🞪
×
Filter
Preview for applied filters×
Air Vent
Air Vent
<strong>Air Vent</strong>
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/air-vent-.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Sprinkler & ZCV, ZCV & Air vent
Flanged Resilient OS& Y Gate Valve UL/FM Approved
Flanged Resilient OS& Y Gate Valve UL/FM Approved
Flanged Resilient OS& Y Gate Valve UL/FM Approved
UL/FM
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/Gate-valve.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, OS&y, Valves
Flanged Resilient Swing Check Valve (C.V 201)
Flanged Resilient Swing Check Valve (C.V 201)
Flanged Resilient Swing Check Valve (C.V 201)
UL/FM
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/Check-Valve.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Check valves, Valves
F242 cylinder valve DN12 for fire suppression systems
F242 cylinder valve DN12 for fire suppression systems
Exemplary illustration of a fire extinguishing system
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/Instruction-manual-cylinder.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Co2 system, Sprinkler & ZCV
F243 solenoid cylinder valve DN12 for fire suppression systems
F243 solenoid cylinder valve DN12 for fire suppression systems
Operating mode: The valves F243 operate according to the pressure difference principle.
By actuating the release device, the integrated pilot valve into the quick-release valve opens and the upper pressure
chamber vents immediately. This pressure drop causes that the cylinder pressure pushes the closing piston in the open position. The quick-release valve is now open.
Design: Total discharge (TD -> total discharge of the cylinder after activation)
The quick-release valves F243 can be triggered electrically, manually and pneumatically.
The cylinder is filled by using the valve outlet (see chapter 11).
For the protection against inacceptable high pressure every valve is equipped with a burst disc safety device.
Quick-release valves for CO2 purposes are not equipped with a pressure gauge connection.
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/ماستر-F243-Instruction-manual-cylinder-valve_en-Rev.-09-1.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Co2 system, Sprinkler & ZCV
F242 cylinder valve DN12 for fire suppression systems
F242 cylinder valve DN12 for fire suppression systems
Operating mode: The valves F242 operate according to the pressure difference principle.
By actuating the release device, the integrated pilot valve into the quick-release valve opens and the upper pressure chamber vents immediately. This pressure drop causes that the cylinder pressure pushes the closing piston in the open position. The quick-release valve is now open.
Design: Total discharge (TD -> total discharge of the cylinder after activation)
The quick-release valves F242 can be triggered manually and pneumatically.
The cylinder is filled by using the valve outlet (see chapter 11).
For the protection against inacceptable high pressure every valve is equipped with a burst disc safety device.
Quick-release valves for CO2 purposes are not equipped with a pressure gauge connection.
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/سيليف-F242-Instruction-manual-cylinder-valve_en-Rev.-09-1.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Co2 system, Sprinkler & ZCV
Vk2543 standard response sidewall sprinkler k8
Vk2543 standard response sidewall sprinkler k8
Specifications:
Available since 2005.
Minimum Operating Pressure: 7 PSI (0.5 bar)
Maximum Working Pressure: 175 PSI (12 bar).
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 1” NPT or 25 mm BSPT
Nominal K-Factor: 8.0 U.S. (115.2 metric*) for lengths up to 48”.
* Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Covered by U.S. Patent numbers: 8,636,075 and 8,376,060 and 10,220,231
Material Standards:
Frame Casting: Brass UNS-C84400
Deflector: Phosphor Bronze UNS-C51000
Bulb: Glass, nominal 5 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Compression Screw: Brass UNS-C36000
Pip Cap and Adapter: Brass UNS-C36000
Orifice: Copper UNS-C11000 or UNS-C21000
Tube: ERW Hydraulic Steel Tube
Inlet and Barrel End: QM Brass or Brass UNS-C31400 or Brass UNS-C31600
Support (Internal): Brass UNS-C36000 or Brass UNS-C31400 or Brass UNS-C31600
Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish
Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/VK2543-Side-wall-SR-.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Sidewall sprinkler, Sprinkler & ZCV, Standard Response
QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0)
QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0)
Specifications:
Available since 2009.
Minimum Operating Pressure: 7 psi (0.5 bar)
Maximum Working Pressure: 175 psi (12 bar).
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread Size: 3/4” (20 mm) NPT
Nominal K-Factor: 8.0 U.S. (115.2 metric*)
* Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-5/8” (66 mm)
Covered by the following US Patent Nos: 7,854,269 and 7,712,218
Material Standards:
Sprinkler Frame: Brass UNS-C84400
Deflector: Brass UNS-C23000 or Phosphor Bronze UNS-C51000
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400
Compression Screws: 18-8 Stainless Steel
Yoke: Phosphor Bronze UNS-C51000
Ejector Spring: 17-7 Stainless Steel
For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pip Cap-ENT Coated
For Polyester Coated Sprinklers: Belleville Spring-Exposed
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/VK360-Side-wall-QR-.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Quick Response, Sidewall sprinkler, Sprinkler & ZCV
MICROMATIC® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6)
MICROMATIC® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6)
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)
Rated to 175 psi (12 bar) water working pressure
Factory tested hydrostatically to 500 psi (34.5 bar)
Nominal K-Factor: 5.6 U.S. (80.6 metric**)
** Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
Glass-bulb fluid temperature rated to -65 °F (-55 °C)
Overall Length: 2-1/2” (64 mm)
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Copper UNS-C19500
Bulb: Glass, nominal 5 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400.
For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pip Cap-ENT Coated
For Polyester Coated Sprinklers: Belleville Spring-Exposed
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/VK104.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Sidewall sprinkler, Sprinkler & ZCV, Standard Response
VK1021 Standard Response Pendent Sprinkler K5.6
VK1021 Standard Response Pendent Sprinkler K5.6
1. PRODUCT IDENTIFICATION
This document covers the following product, hereafter
referred to as “sprinkler”:
VK1021: Standard Response, Standard Coverage,
Pendent, K5.6 (80.6) Sprinkler.
2. INTENDED USE
The sprinkler is intended to be used in automatic fire
sprinkler systems as allowed by applicable approval
authorities. The sprinkler must be used in accordance
with:
1. the sprinkler’s Listings, Approvals, and associated
design requirements.
2. the recognized design and installations standards
issued, for example NFPA, FM, EN, VdS, or LPCB.
3. the latest revisions of all applicable manufacturer’s
documentation.
Governmental codes, ordinances, and standards may apply and may differ from one another.
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/VK1021.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Pendent Sprinkler, Sprinkler & ZCV, Standard Response
VK2001 Standard Response Upright Sprinkler K8.0 (115)
VK2001 Standard Response Upright Sprinkler K8.0 (115)
1. PRODUCT IDENTIFICATION
This document covers the following product, hereafter
referred to as “sprinkler”:
VK2001: Standard Response, Standard Coverage,
Upright, K8.0 (115) Sprinkler.
2. INTENDED USE
The sprinkler is intended to be used in automatic fire
sprinkler systems as allowed by applicable approval
authorities. The sprinkler must be used in accordance
with:
1. the sprinkler’s Listings, Approvals, and associated
design requirements.
2. the recognized design and installations standards
issued, for example NFPA, FM, EN, VdS, or LPCB.
3. the latest revisions of all applicable manufacturer’s
documentation.
Governmental codes, ordinances, and standards may apply and may differ from one another.
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/VK2001.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Sprinkler & ZCV, Standard Response, upright Sprinkler
VK3501 Quick Response Upright Sprinkler K8.0 (115)
VK3501 Quick Response Upright Sprinkler K8.0 (115)
1. PRODUCT IDENTIFICATION
This document covers the following product, hereafter
referred to as “sprinkler”:
VK3501: Quick Response, Standard Coverage,
Upright, K8.0 (115) Sprinkler.
2. INTENDED USE
The sprinkler is intended to be used in automatic fire
sprinkler systems as allowed by applicable approval
authorities. The sprinkler must be used in accordance
with:
1. the sprinkler’s Listings, Approvals, and associated
design requirements.
2. the recognized design and installations standards
issued, for example NFPA, FM, EN, VdS, or LPCB.
3. the latest revisions of all applicable manufacturer’s
documentation.
Governmental codes, ordinances, and standards may apply and may differ from one another.
<h5><a href="https://www.sheter.net/wp-content/uploads/2024/11/VK3501-1.pdf" target="_blank" rel="noopener"><span style="color: #ff0000;">Download Catalog</span></a></h5>
Categories: All Products, Quick Response, Sprinkler & ZCV, upright Sprinkler